The High-Precision Resistance aAcquisition Analyzer adopts an integrated sealed explosion-proof chamber, and the connection end of the probe sensor is made of high-temperature glass sintered seal and gold-plated pin connection, and is sealed with a double fluororubber sealing ring.The wired working power supply is 24VDC, and the output signal is RS485 signal; The working power supply for wireless and data recording forms is self powered by lithium batteries, outputting wireless signals such as LORA, 4G, or Bluetooth.
The High-Precision Resistance aAcquisition Analyzer adopts an integrated sealed explosion-proof chamber, and the connection end of the probe sensor is made of high-temperature glass sintered seal and gold-plated pin connection, and is sealed with a double fluororubber sealing ring.
The wired working power supply is 24VDC, and the output signal is RS485 signal; The working power supply for wireless and data recording forms is self powered by lithium batteries, outputting wireless signals such as LORA, 4G, or Bluetooth.
The acquisition instrument consists of measurement, logic, and power modules, all of which have been accurately calibrated before leaving the factory. No on-site verification is required, just perform standard configuration directly based on the ID provided by the instrument, making the operation convenient and fast.
Line No |
Parameter |
Technical Overview |
1 |
18 bit resolution |
1/262144 |
2 |
Probe impedance range |
1-50mΩ |
3 |
Power Supply |
24VDC |
4 |
Current consumption |
12mA@24VDC/1-12mA@8.4V |
5 |
communication |
RS485,2400Baud rate/2.4G、Lora、4G/5G |
6 |
RS485 communication address |
0-31 |
7 |
ambient temperature |
-40℃~+70℃ |
8 |
Shell protection level |
IP65 |
9 |
Maximum collection rate |
Once a minute |
10 |
Minimum collection rate |
Once Custom Time |
11 |
Hazardous Area Certification |
Ex d IICT4 Gb |
Wireless Ultrasonic Fixed-Point Thickness Device